MODEL SPEC
Model | Thread Connection ( PT ) | Max. Operational Pressure ( bar ) | Weight ( kg ) |
MFP-02 | 1/4″ | 320 | 3.0 |
* The pressure indicator are not included in weight.
ORDER CODES
- MFP-02
- MFP – 02 – 05 – S2
a – b – c – d - Model Name : MFP
- Thread Connection : 02:PT 1/4”
- Filtration :
- 05: 5um (β5 >100-ISO 4406:1999, level17/15/12)
- 10: 10um (β10 >100-ISO 4406:1999, level 18/16/13)
- 25: 25um (β25 >100-ISO 4406:1999, level 19/17/14)
- Type of Pressure Indicator : S1:visual, S2:visual-electrical
- MFP – 02 – 05 – S2
- ELEMENT
SE – MFP-02– A10
a – b – c- Elements Model Name : SE
- Filter Model Name: MFP-02
- Type of Filter Element : A5, A10, A25, 400M, 700m, etc
DOCUMENATION
SYMBOLS
HOUSING PRESSURE DROP CURVE
MATERIAL OF FILTERING ELEMENT
- M represents metal material, a indicates glass fiber.
- Regular order of metal element : 100M, 200M, 300M, 400M, 700M, etc.
- Regular order of glass fiber element : A5, A10, A25, etc.
MESH TO MICRON CONVERSION CHART
Mesh | um |
20 | 850 |
40 | 425 |
60 | 250 |
100 | 150 |
120 | 125 |
150 | 106 |
200 | 75 |
250 | 63 |
300 | 50 |
400 | 40 |
700 | 25 |
1450 | 10 |
DIMENSION (UNIT:mm)
- MFP-02
- ELEMENT