Model | JC-DPS-NS |
Pressure Range ( bar ) | 150, 250, 350, 420 |
Burst Pressure | Min. 10000 psi |
Accuracy | ±1% F.S. @ 25±3°C |
Supply Voltage | 10 to 30 VDC |
Current Consumption | <20 mA (not including switch output) |
Protection | Power reverse protection, over load protection |
Output | NPN or PNP mode, with 100 mA, 30 VDC (max.) |
Analog Current Output ( option “I” ) | 4~20mA, 0~20mA, 0~24mA option selected by panel operation |
Analog Voltage Output ( option “V” ) | 0~5V, 0.5~4.5V, 1~5V, 0~10V, 1~10V, option selected by panel operation |
Power Connector | M12 (6 pin) |
Working Temperature | -10~60°C (14~140˚F), Non-frozen state |
Storage Temperature | -40~85°C (40~185°F), Non-frozen state |
Chemical Compatibilities | gas / liquid compatible with 304L & 316L |
Material | Front & Rear Cover: ABS, Port: SUS304L/SUS316L |
Waterproof | IP65 |
Weight ( kg ) | 0.15 |
Analog Output Format Option
Analog Current Output | |
4~20mA | Zero pressure: 4mA, Full pressure: 20mA |
0~20mA | Zero pressure: 0mA, Full pressure: 20mA |
0~24mA | Zero pressure: 0mA, Full pressure: 24mA |
Analog Voltage Output | |
0~5V | Zero pressure: 0V, Full pressure: 5V |
0.5V~4.5V | Zero pressure: 0.5V, Full pressure: 4.5V |
1~5V | Zero pressure: 1V, Full pressure: 5V |
0~10V | Zero pressure: 0V, Full pressure: 10V |
1~10V | Zero pressure: 1V, Full pressure: 10V |
JC-DPS-NS – 420 – 1
a – b – c
- Model Name : JC-DPS-NS (w/Pressure Transducer)
- Used Pressure : 150, 250, 350, 420 (bar)
- Thread Connection :
- 1/4” PT
- 1/4” NPT
- 1/4” BSPP
SWITCH CONTROL TYPE PARAMETER
The real output is depends on the output type and control type. For example, if the high threshold setting is 45.00 psi and low threshold setting is 37.00 psi, the switch output will be shown as below figure. The switch output is turned on when it is active.
WIRING INSTRUCTION
The application circuit for NPN or PNP output.